board: qca: ipq5332: updated scope for the loop in PHY reset

The missing calibrace leads to an in-valid hardware access,
it in-turn causes silent reboot. So, added the calibrace to
define the scope for the loop statement.

Change-Id: I0c719798af35eb21a824ee6f570501dab720e241
Signed-off-by: Ram Kumar D <quic_ramd@quicinc.com>
(cherry picked from commit 17f2872c6b)
This commit is contained in:
Ram Kumar D 2024-02-02 16:36:59 +05:30 committed by Rajkumar Ayyasamy
parent a355661408
commit 98fa31b9d4

View file

@ -1200,11 +1200,12 @@ void aquantia_phy_reset_init_done(void)
aquantia_gpio_cnt = get_aquantia_gpio(aquantia_gpio); aquantia_gpio_cnt = get_aquantia_gpio(aquantia_gpio);
if (aquantia_gpio_cnt >= 1) { if (aquantia_gpio_cnt >= 1) {
for (i = 0; i < aquantia_gpio_cnt; i++) for (i = 0; i < aquantia_gpio_cnt; i++) {
gpio_set_value(aquantia_gpio[i], 0x1); gpio_set_value(aquantia_gpio[i], 0x1);
writel(0x3, GPIO_IN_OUT_ADDR(aquantia_gpio[i])); writel(0x3, GPIO_IN_OUT_ADDR(aquantia_gpio[i]));
mdelay(500); mdelay(500);
} }
}
} }
void qca808x_phy_reset_init_done(void) void qca808x_phy_reset_init_done(void)