mirror of
https://dev.iopsys.eu/feed/iopsys.git
synced 2025-12-10 07:44:50 +01:00
The runner hardware on both the chips are different due to which the operation of counter read on dg400prime and eg400 units is actually a read and reset. As a result cumulative counter values are not available. To uniformalise the behaviour of qosmngr across platforms, handling is added to represent cumulative value of counters. Test: Scripts that were earlier failing on dg400prime and passing on panther in the QoS L3 suite were executed and with this fix scripts pass on both the platforms. This is a good enough indicator beside the manual tests, that the issue now stands resolved. Note: pending scripts can now be closed with this fix. |
||
|---|---|---|
| .. | ||
| files | ||
| Makefile | ||